Basic Info & Specifications
| Size |
110*80*90cm |
| Sealing Method |
Totally Enclosed |
| Cooling Mode |
Evaporative |
| Capacity |
Medium/Low Temp (-25~10) |
| After-Sales Service |
24hr Services |
| Fan |
Axial&Centrifugal |
| Coil |
Copper |
| Fin |
Aluminium Alloy |
| System |
Monoblock |
| System Type |
Combined |
| Fans Species |
Single-Speed Fan |
| Noise Level |
Low |
| Certification |
ISO, CCC |
| Condition |
New |
| Cooling Water |
City Water |
| Application Fields |
Cold Room, Freezer |
| Transport Package |
Wooden Frame |
| Specification |
450x940x975 |
| Origin |
China |
| Production Capacity |
10000 |
Packaging & Delivery
| Package Size |
100.00cm * 70.00cm * 80.00cm |
| Package Gross Weight |
550.000kg |
Product Description
A01W / A01T Series Monoblocks
A01W Wall straddle Monoblock & A01T Through wall Monoblock applies to various cold storages. The unit can be installed on the wall, and can be assembled with multi units stacked together. Cases of the Monoblock are with Epoxy sprayed steel plates. Hermetic piston compressors are applied, with R404A as the refrigerant.
Standard Configuration
- Low noise Hermetic compressor
- One time formulation casing for evaporator
- Auto defrosting system
- Condenser over-dirt alarm system
- Condensate water evaporation tray
- Expansion through capillary tube system
- Filter on the liquid line
- Cold room light and bulb
- Cable for door micro switch
- Cable for door switch heater on low temperature units
- High- and low-pressure switches
- Remote electronic control panel
Optional Accessories & Configuration
Power Supply Options:
230 / 1~ / 50
400 / 3N~ / 50
208-230 / 1~ / 60
230 / 3~ / 50
208-230 / 3~ / 60
440-460 / 3N~ / 60
440-460 / 3~ / 60
108-115 / 1~ / 60
Electrical Accessories:
- Prearrangement for supervision system
Accessories Kit:
- Audible and visual alarm
- Remote control panel for 2-3-4 units
Condensation Type:
- Air + Axial Fan
- Air + Centrifugal fan
- City water with pressure valve
Winter Kit (Low Ambient Temp Accessories):
- Crankcase heater + Condenser fan pressure switch + Double solenoid valve for defrosting
- Crankcase heater + Pressure controlled condenser fan speed regulator + Double solenoid valve for defrosting
Product Parameters
Medium Temperature Arguments - A01W
| Model |
WMA010C2 |
WMA015C2 |
WMA018C2 |
WMA025C2 |
| Compressor (HP) |
1HP |
1.5HP |
1.8HP |
2.5HP |
| Power supply |
220V/1P/50Hz |
220V/1P/50Hz |
380V/3P/50Hz |
380V/3P/50Hz |
| Condenser Air flow rate (m³/h) |
630m³/h |
1260m³/h |
2670m³/h |
2670m³/h |
| Evaporator air flow rate (m³/h) |
745m³/h |
1490m³/h |
2670m³/h |
2670m³/h |
| Installation power (kw) |
0.995kw |
1.477kw |
1.662kw |
2.135kw |
Low Temperature Arguments - A01W
| Model |
WLA010C2 |
WLA015C2 |
WLA020C2 |
WLA030C2 |
WLA040C2 |
| Compressor (HP) |
1HP |
1.5HP |
2HP |
3HP |
4HP |
| Power supply |
220V/1P/50Hz |
220V/1P/50Hz |
380v/3P/50hz |
380v/3P/50hz |
380v/3P/50hz |
| Condenser Air flow rate (m³/h) |
630m³/h |
1260m³/h |
1260m³/h |
2670m³/h |
2670m³/h |
| Evaporator air flow rate (m³/h) |
745m³/h |
1490m³/h |
1490m³/h |
2670m³/h |
2670m³/h |
| Installation power (kw) |
0.86kw |
1.243kw |
1.538kw |
1.992kw |
2.539kw |
Medium Temperature Arguments - A01T
| Model |
TMA035C2 |
TMA045C2 |
TMA055C2 |
TMA065C2 |
| Compressor (HP) |
3.5HP |
4.5HP |
5.5HP |
5HP |
| Power supply |
380V/3P/50Hz |
380V/3P/50Hz |
380V/3P/50Hz |
380v/3p/50hz |
| Condenser Air flow rate (m³/h) |
3600m³/h |
5400m³/h |
5400m³/h |
7200m³/h |
| Evaporator air flow rate (m³/h) |
6000m³/h |
9000m³/h |
9000m³/h |
11181m³/h |
| Installation power (kw) |
3.5kw |
4.8kw |
5.4kw |
6.9kw |
Low Temperature Arguments - A01T
| Model |
TLA065C2 |
TLA085C2 |
TLA105C2 |
TLA135C2 |
| Compressor (HP) |
6.5HP |
1.5HP |
1.8HP |
2.5HP |
| Power supply |
380V/3P/50Hz |
380V/3P/50Hz |
380V/3P/50Hz |
380V/3P/50Hz |
| Condenser Air flow rate (m³/h) |
3600m³/h |
5400m³/h |
5400m³/h |
7200m³/h |
| Evaporator air flow rate (m³/h) |
6000m³/h |
9000m³/h |
9000m³/h |
11181m³/h |
| Installation power (kw) |
6.4kw |
7.6kw |
9.3kw |
12.1kw |
How to Install AIOB Mono Block
- The installation of the A01W and A01T series mono block is installed on the wall.
- The evaporator part is designed to be placed on the wall or through the wall.
- The condensing part lays outside the cold room.
- The unit must be positioned in an environment with good air circulation, away from high heat sources and away from obstacles that could limit the possibility of good suction and equally good discharge of the treated air.
Application, Customers & Transport
Application Fields
Our Customers
Packing & Transport
Frequently Asked Questions
1How long is the delivery time?
It takes within 1 month from receipt of the deposit to preparation of the goods.
2How long is the quality guarantee period?
The warranty period is 1 year, and the after-sales service is available 24 hours.
3What is your price terms?
Our FOB price is based on quantity, material and size you required. The more machines you order, the lower price we will give! Also CIF and CNF prices are the same.
4What customization services can you do?
All materials and sizes are available, and we can customize products according to your specific requirements.
5Where can these monoblock refrigeration units be applied?
They are widely applied in various cold storage environments, specifically suited for cold rooms and freezers requiring medium to low temperatures (-25°C to 10°C).
6What type of compressor and casing design are used in these units?
The units utilize low noise hermetic piston compressors with R404A refrigerant. The evaporator casing features a durable one-time formulation design, and the monoblock cases are made of epoxy sprayed steel plates.